🖥️ Hardware inventory and sensors (daemon)
🌍 Language: English · 🇷🇺 Русская версия
📌 Description
What the node is made of, and how hot it is. The daemon builds a hardware inventory — machine type and virtualization, CPU, motherboard and firmware, memory modules, disks, GPUs — and reads the temperature and fan sensors of every device that has one. It is the data behind the platform's node Resources tab and behind the GPU picker in an app's settings, and it is available on its own through asc hardware.
Everything is read from procfs and sysfs. No new dependencies, and no serial numbers: the inventory is made to be shown in a UI and pasted into a support request, not to fingerprint the machine.
🎯 Scenarios
asc hardware— a readable summary: machine, CPU, board, memory, disks, GPUs and current temperatures.asc hardware --jsonprints the same as one JSON document for scripts.- "Is this a real server or a VPS, and which hypervisor?" —
machine_typeandvirtualization. - "Which GPU can I give to the container?" — the GPU list shows each card's PCI address and whether it can be attached.
- "What is overheating?" — the sensors are grouped per device: CPU package and cores, GPU, NVMe/SATA drives, motherboard chip, DIMMs, network cards, fans.
- The platform reads the same data through
MonitorService.GetHardwareInfoand the metrics stream.
🏗️ Technical design
🧱 Inventory
src/daemon/monitor/hardware.rs. API: MonitorService.GetHardwareInfo (gRPC), REST GET /v1/hardware[?refresh=1], capability hardware. The answer is cached for ten minutes — hardware barely changes while the daemon runs, and gathering it spawns helper processes — unless refresh is set.
| Block | Source |
|---|---|
| Machine type and virtualization | systemd-detect-virt; without it: PID 1's container=, /.dockerenv, /proc/vz (OpenVZ), the hypervisor CPU flag, WSL's kernel release, and DMI vendor/product strings (QEMU/KVM, VMware, Hyper-V, VirtualBox, Xen, Amazon EC2, Google Cloud, DigitalOcean, Hetzner, OpenStack…) |
| System, board, BIOS | /sys/class/dmi/id/*, with the usual "To Be Filled By O.E.M." placeholders dropped |
| CPU | /proc/cpuinfo: vendor, model, sockets, physical cores (unique physical id/core id pairs), threads, maximum frequency (cpufreq); ARM boards report the licensee from CPU implementer |
| Memory | total from /proc/meminfo; modules from the SMBIOS table (type 17 Memory Device): slot, size, type (DDR4/DDR5/LPDDR5…), rated and configured speed, manufacturer, part number |
| Disks | /sys/block/* without loop/ram/zram/device-mapper/RAID/optical devices: model, size, kind (nvme, ssd, hdd, virtual), bus (nvme, sata, scsi, usb, virtio, mmc) |
| GPUs | PCI devices of class 0x03: PCI address, vendor, model, VRAM, bound driver, DRM render/card nodes, NVIDIA UUID |
machine_typeisbare_metal,virtual_machine,containerorunknown. A container is decided first: it shares the host's kernel, so the CPU flags and DMI it sees are the host's.- A virtual machine often hides DMI and the SMBIOS memory table. Those fields stay absent (never faked), and the UI says the provider does not expose them.
- GPU model: NVIDIA from
nvidia-smi --query-gpu=pci.bus_id,uuid,name,memory.total(only run when an NVIDIA card is bound to the proprietary driver); otherwiseproduct_name, then the system'spci.idsdatabase, thenvendor:device. - Attachability (
attachable/attach_hint): an NVIDIA card needs the proprietary driver bound and the NVIDIA Container Toolkit installed (driver_not_loaded,toolkit_missing); AMD and Intel cards need a DRM render node (no_render_node); anything else isunsupported_vendor.
🌡️ Sensors
src/daemon/monitor/sensors.rs. A temperature is a metric, not an inventory item, so the readings ride in SystemMetrics.temperatures / fans — on GetSystemMetrics, StreamSystemMetrics and REST GET /v1/metrics, and in asc hardware. They are read at most once a second (capability sensors).
- Source:
/sys/class/hwmon/hwmon*(temp*_input,_label,_max,_crit,fan*_input); when hwmon is empty (ARM boards),/sys/class/thermal/thermal_zone*. - Each reading is attached to its device —
kindanddevice_id— by the chip's driver and the device node it hangs off:
kind | Drivers | device_id |
|---|---|---|
cpu | coretemp, k10temp, zenpower, cpu_thermal | cpu |
gpu | amdgpu, radeon, nouveau, i915, xe | the PCI address, the same id as in the GPU list |
disk | nvme, drivetemp | the NVMe controller or block device name |
board | nct67xx, it87, w83*, acpitz, pch_* | board |
memory | jc42, spd5118 | the DIMM's bus address |
network | network cards with hwmon | the interface name |
other | everything else | the chip name |
- NVIDIA cards have no hwmon node: their temperature stays in
GpuMetrics.temperature_c. - Channels that read zero or an out-of-range value (a header with nothing wired to it) are dropped.
max_c/crit_care the driver's thresholds, absent when it has none. - A virtual machine normally has no sensors; an empty list is a valid answer.
🎮 GPU passthrough
Selecting GPUs for an app is described in 📦 package-manager: the $gpus setting holds PCI addresses from this inventory, and the daemon translates them into a DeviceRequest (NVIDIA) or device mappings (AMD/Intel) when it creates the container.
⌨️ CLI
asc hardware [--json] reads everything in-process, like the metrics block of asc status — no running daemon needed. Output is translated (EN/RU); --json is language-neutral.